Overview

Where decontamination of small-scale items is needed PBSC produces a dunk tank system for installation on the containment barrier.

The dunk tank serves as a specialised pass-through system for transferring goods between sections of a cleanroom or biology laboratory, using liquid disinfection to ensure effective sterilisation.

The chemical dunk tank is specifically designed for use in BSL3 and BSL4 biosafety laboratories.

Read more

Innovation. Design. Quality.

The dunk tank is constructed from 5mm and 3mm stainless steel, including a center baffle, guide bars, overflow/top-up pipe to one side, and locking stainless steel lids.

The dunk tank is supplied with a stainless steel back plate which is bolted to the wall and grouted to the floor. This includes a double-glazed vision panel above the tank with a viewing area of approximately 570mm x 600mm and rubber bump stops on both sides. A stainless steel support frame with adjustable feet and retrieval claw are supplied as standard.

Lids:

  • Stainless steel 316
  • Phenolic Resin (High-Performance laminate)

 

Available in various configurations to suit specific operational needs.

Following on-site installation, PBSC offers a Planned Preventative Maintenance and Servicing Plan with an extensive after-sales support service, including planned preventative maintenance programs, servicing, and spare parts.

 

READ MORE

Features

  • Suitable for BSL3 and BSL4 containment barriers
  • Air tight performance from the lids without the liquid in the tank
  • Mesh transfer system
  • Design solutions to suit stud, block or cast concrete walls
  • Decontamination for small-scale items
  • A reliable solution
  • Air tight performance

Applications

Suitable for BSL3 and BSL4 containment barriers.

Biosafety dunk tanks are widely utilised in pharmaceutical manufacturing and biotechnology, where maintaining stringent cleanliness and environmental control is essential to prevent product or process contamination.

Technical Specification

  • Typical pressure loss at SAT of 80Pa over 30 minutes
  • Starting pressure of 500Pa
  • Suitable for BSL3 and BSL4 containment
  • -
  • Please contact PBSC for specific design options.
  • PBSC reserve the right to introduce changes in performance, configuration and technology, dimension, weights and materials in the course of technical progress. Images may not be accurate.
  • Some of the information/images/equipment described or shown may only be available at extra cost. Features & specifications will vary.

Options

  • Internal light to aid visibility
  • Liquid Level Sensor
  • Pneumatic interlock with PLC controls
  • Sink to side
  • Vision panel above unit
  • Clean side gassing ports
  • Customized Designs
  • Design solutions to fit different types of concrete walls